QT-FIT8 1x18 Quicktronic fit T8

£8.00

20 in stock

Description

Product family features

– Supply voltage: 220…240 V
– Line voltage: 198…264 V
– Line frequency: 50 Hz | 60 Hz
– Lamp start with optimum filament preheating
– Energy Efficiency Index EEI: A2
– Automatic shutdown of defective lamps at end of life (EoL T.2)
– Lamp operation: to EN 60929
– Safety: to EN 61347-2-3

 

Product family benefits

– Long lamp life
– No adverse effect from frequent on/off switching
– Automatic restart after lamp replacement
– Perfect lamp start for applications with motion sensors
– VDE/VDE EMC certified system
– Very high energy efficiency due to cut-off technology

 

Areas of application

– Open-plan offices, corridors, and storage rooms
– Public buildings
– Strip lighting
– Suitable for emergency lighting (DC operation)
– Suitable for luminaires of protection class I

Additional information

Weight 0.18 kg
Dimensions 28.0 × 3 × 2.8 cm
Input voltage AC

198/264 V

Nominal voltage

220/240 V

Mains frequency

50/60 Hz

Input voltage DC

185/264 V

Maximum output power

18 W

Efficiency in full-load

84 %

Operating frequency

40/50 kHz

Max. ECG no. on circuit breaker 10 A (B)

17

Max. ECG no. on circuit breaker 16 A

28

Inrush current

15 A

Starting time

2.0 s

Moutning hole spacing, length

270.0 mm

Cable cross-section, output side

0.5…1.5 mm²

Cable cross-section, input side

0.5…1.5 mm²

Ambient temperature range

-15-+50 °C

Permitted rel. humidity during operation

5-85 %

ECG Lifetime

50000 h

Suitable for lamp power (1 lamp)

18 W

End of lamp life safety shutdown

EOL T.2

Max. cable length to lamp/LED module

2.0 m / 1.0 m

Dimmable

No

Intended for no-load operation

No

Approval marks – approval

VDE / VDE-EMC / ENEC 10 / CE

EEI – Energy Label

A2

Standards

Acc. to EN 61347-2-3/Acc. to EN 60929/Acc. to EN 55015:2006 + A1:2007/Acc. to EN 61000-32/Acc. to EN 61547

Protection class

I

Type of protection

IP20